Boiler-Specific Filling Loop Guides

  • 25+ Years’ Experience
  • Fixed Price Investigation
  • Trace & Repair Service
  • 12-Month Warranty
Boiler specific filling link

Boiler-Specific Filling Loop Guides

Different boiler manufacturers use slightly different systems for repressurising. Here’s a breakdown of how to use the filling loop on some of the most common brands in the UK:


🔧 Ideal Boilers (F1 Fault Code)

  • Look for a silver braided hose beneath the boiler with two black taps.
  • Turn both taps slowly so they line up with the pipe.
  • Watch the pressure gauge climb to 1.0–1.5 bar.
  • Close both taps firmly.
  • If the F1 code remains, reset the boiler.

Newer models use a fixed link with 2 x blue knobs. operation is the same


🔧 Baxi Boilers (E119 Fault Code)

  • On most Baxi combi models (200 & 400 range), the filling loop is located underneath.
  • You’ll see a tap with a blue or black handle.
  • Turn it slowly to let water into the system.
  • Once the gauge reaches the correct pressure, close the tap.
  • Clear the E119 error code by resetting the boiler if needed.

older models will have 2 x blue or black taps on fixed pipework. (it may have been removed and capped. It should have been kept with the boiler)


🔧 Vaillant Boilers (F22 Fault Code)

  • Vaillant often uses an internal filling loop.
  • There’s usually 2x small grey plastic levers beneath the boiler.
  • Turn one lever fully and the control the flow with the second until the pressure gauge rises to 1.2 bar.
  • Turn both back fully to close.
  • The F22 low-pressure code should disappear automatically.

The newer ecofit range have 2 x fixed black knobs with flat head screw holes in them . the procedure is the same.


🔧 Worcester Bosch Boilers (Flashing Blue Light / Error 1017 GZ)

  • Some Worcester models use a keyed filling link.
  • Insert the Worcester filling key into the slot underneath the boiler.
  • Turn it to lock (it’s a bayonet connection), then slowly rotate the white tap to allow water in.
  • When pressure reaches 1.0–1.5 bar, close the tap and remove the key.
  • If your boiler has an external braided hose, use it like other brands by opening both taps.

There is also an option with a blue lever instead of a key. Just pull the blue lever down, its spring loaded and so will close naturally.


🔧 Main Boilers (E119 Fault Code)

  • Main Heating boilers are part of the same group as Baxi, and use similar filling loops.
  • Locate the braided hose beneath the boiler with two taps.
  • Turn them both slowly to allow water in.
  • Close firmly once pressure is back to normal.
  • The E119 code should clear after reset.

🔧 Glow-worm Boilers (F22 / F75 Fault Codes)

Glow-worm boilers often share components with Vaillant, meaning the repressurising process is similar.

How to repressurise a Glow-worm boiler:

  1. Locate the filling loop, usually a silver braided hose beneath the boiler.
  2. Open the two taps slowly so they align with the pipe.
  3. Watch the pressure gauge until it rises to 1.0–1.5 bar.
  4. Close both taps securely.
  5. Reset the boiler if the F22 (low pressure) or F75 (pump/pressure issue) code remains.

Older models have a blue tap underneath, newer boilers have a 2 x knob with screw head system. see below:


🔧 Ariston Boilers (108 / 109 Fault Codes)

Ariston boilers typically show fault code 108 for low pressure, or 109 if the system can’t detect water.

How to repressurise an Ariston boiler:

  1. Find the built-in filling loop, usually with black or grey levers beneath the boiler.
  2. Open the levers carefully to allow water into the system.
  3. Keep an eye on the pressure gauge, topping up to 1.2 bar when cold.
  4. Close the valves firmly once complete.
  5. Reset the boiler if necessary to clear the fault code.

🔧 ATAG Boilers (118 / 101 Fault Codes)

ATAG boilers are high-efficiency systems, and low pressure often triggers error 118 (low water pressure) or 101 (general no ignition, often linked to pressure).

How to repressurise an ATAG boiler:

  1. Look for the integrated filling loop beneath the boiler. Some ATAG models use a built-in lever system rather than a separate hose.
  2. Turn the lever slowly to let water in.
  3. Monitor the gauge until it reaches 1.0–1.5 bar.
  4. Turn the lever back to the closed position.
  5. Restart the boiler if the 118 or 101 fault code remains.

Safety Reminder ⚠️

  • Never overfill your boiler — do not exceed 2.0 bar.
  • (don’t worry if you do it’s just an indication of how much water is in the system and not dangerous)
  • Always close the filling loop securely after use.
  • If pressure drops repeatedly, keep topping up to keep the boiler on. However, this usually means there’s a hidden leak in the system that requires professional detection.

For a full breakdown of causes and pressure behaviour, see our central heating leaks explained guide.

If your system is losing pressure or showing signs of a leak, it’s important to identify the cause rather than repeatedly topping it up. Our central heating leak detection service will locate the issue accurately.

Explore more expert advice in our Helpful Guides.

Need help with a leak? We’ll find it and fix it.

If you’re dealing with a similar issue, The Leak Hunter will diagnose the problem, explain the cause clearly, and recommend the most cost-effective next step.

We deal with water, central heating, underground and gas leaks using accurate, non-invasive methods.

Call 01372 613053

POST FORM CTA bottom

Fixed price diagnostic options available. All costs are agreed with you before work begins.

Find the best way to get in touch — see all contact options.

Get in Touch